“Water sw open”. Raypak 266 digital. (2024)

uxbridgechris

0

Bronze Supporter

Jan 25, 2018
655
uxbridge, Ontario Canada
  • May 29, 2020
  • Add bookmark
  • #1

My heater is doing funny things today. Error code “water sw open”. Google isn’t being much help. Any thoughts are appreciated.

uxbridgechris

0

Bronze Supporter

Jan 25, 2018
655
uxbridge, Ontario Canada
  • May 29, 2020
  • Add bookmark
  • #3

Ya I read that thanks. It’s the first hit in google. The question is answered by an appliance repair guy that just googled possible answers. Lol.
Raypak says “check to make sure there are no obstructions. Clean skimmer and pump basket and filter”. That’s not the issue here. I am clean. water is moving thru the system at 60gpm like always.

uxbridgechris

0

Bronze Supporter

Jan 25, 2018
655
uxbridge, Ontario Canada
  • May 29, 2020
  • Add bookmark
  • #4

The heater sounds like it’s trying to fire. “Spark” is flashing and so is “no demand”. I am not calling for heat.

  • May 29, 2020
  • Add bookmark
  • #5

Ok. I’ve been working on it for the last hour. I unpowered it and powered back on.

if the heater is in “Remote mode”. It will fire up even if my automation isn’t calling for heat. I have even gone so far as to unhook my automation and it still fires up even know there is no call for heat.

Manual mode, it is functioning as normal.

kimkats

Mod Squad

LifeTime Supporter

Jul 10, 2012
54,966
Tallahassee, FL
  • May 29, 2020
  • Add bookmark
  • #6

Make sure to keep notes of what you have done so far and do coming up so we can trace back to what worked.

@ajw22 @jimmythegreek @Pool Clown @bdavis466 or any others that might have input please just in!

ajw22

TFP Expert

Gold Supporter

Silver Supporter

Bronze Supporter

TFP Guide

Jul 21, 2013
55,050
Northern NJ
Pool Size
35000
Surface
Plaster
Chlorine
Salt Water Generator
SWG Type
Pentair Intellichlor IC-60
  • May 29, 2020
  • Add bookmark
  • #7

I am confused. Are you past the "water switch open" problem and the heater is running?

Describe your current problem.

  • “Water sw open”. Raypak 266 digital. (10)

Reactions:

steevo

uxbridgechris

0

Bronze Supporter

Jan 25, 2018
655
uxbridge, Ontario Canada
  • May 29, 2020
  • Add bookmark
  • #8

When I came around the corner to my heater this morning I could hear the electronic ignition trying to start every few seconds. Pump was not running because I had it turned off. The display was alternating “no demand” and “water sw open”.

I unplugged the heater

When I plugged the heater back in, “water sw open” was gone. I turned pump on circulate but made sure heat was off On my controller. The heater kicked into “spark” and fired up even know my controller was not calling for heat. I powered heater off and disconnected the 2 wire connection to the controller. Again, when I powered heater on, it fired up.

I switched heater from “remote” to “manual” and the heater functions as it should. In my opinion when Heater is on “remote” mode, the heater is always acting like there is a call for heat.

ajw22

TFP Expert

Gold Supporter

Silver Supporter

Bronze Supporter

TFP Guide

Jul 21, 2013
55,050
Northern NJ
Pool Size
35000
Surface
Plaster
Chlorine
Salt Water Generator
SWG Type
Pentair Intellichlor IC-60
  • May 29, 2020
  • Add bookmark
  • #9

uxbridgechris said:

When I came around the corner to my heater this morning I could hear the electronic ignition trying to start every few seconds. Pump was not running because I had it turned off. The display was alternating “no demand” and “water sw open”.

That was what would be expected with the pump not running. “water sw open” means there is no water flow which there was not.

uxbridgechris said:

I unplugged the heater

No reason to do that. Just turn on the pump.

uxbridgechris said:

When I plugged the heater back in, “water sw open” was gone. I turned pump on circulate but made sure heat was off On my controller. The heater kicked into “spark” and fired up even know my controller was not calling for heat. I powered heater off and disconnected the 2 wire connection to the controller. Again, when I powered heater on, it fired up.

Where did you disconnect the 2 wire "firemans switch"?

uxbridgechris said:

I switched heater from “remote” to “manual” and the heater functions as it should. In my opinion when Heater is on “remote” mode, the heater is always acting like there is a call for heat.

So that says you need to open up the heater and see what is going on with the 2 wire connection there. It sounds like the 2 wires are shorted in the heater. Maybe a critter got inside and chewed the wire.

uxbridgechris

0

Bronze Supporter

Jan 25, 2018
655
uxbridge, Ontario Canada
  • May 29, 2020
  • Add bookmark
  • #10

alw22. I am 99% sure you solved the problem. The 2 wire from my controller was too short in 2018 when I installed it so I spliced it. I cut the wire before the splice and the problem of it wanting to fire up had stopped. My multimeter is at work but I suspect that splice is bad and maybe a strand is poking thru. Thanks so much. Will follow up when I repair and test. Raining here now.

Enjoying this content?

Support TFP with a donation.

Give Support

ajw22

TFP Expert

Gold Supporter

Silver Supporter

Bronze Supporter

TFP Guide

Jul 21, 2013
55,050
Northern NJ
Pool Size
35000
Surface
Plaster
Chlorine
Salt Water Generator
SWG Type
Pentair Intellichlor IC-60
  • May 29, 2020
  • Add bookmark
  • #11

uxbridgechris said:

alw22. I am 99% sure you solved the problem. The 2 wire from my controller was too short in 2018 when I installed it so I spliced it. I cut the wire before the splice and the problem of it wanting to fire up had stopped. My multimeter is at work but I suspect that splice is bad and maybe a strand is poking thru. Thanks so much. Will follow up when I repair and test. Raining here now.

And now we have "the rest of the story". “Water sw open”. Raypak 266 digital. (15)

uxbridgechris

0

Bronze Supporter

Jan 25, 2018
655
uxbridge, Ontario Canada
  • May 29, 2020
  • Add bookmark
  • #12

Hahha. Ya. There is always a detail that is left out that seems insignificant at the time.....I took great care in that splice. Staggered and soldiered it. Now that I think about it, it probably has water in it. Ouch. I’m going to fix that more carefully. Thanks again so much.

kimkats

Mod Squad

LifeTime Supporter

Jul 10, 2012
54,966
Tallahassee, FL
  • May 29, 2020
  • Add bookmark
  • #13

Allen in for the win AGAIN!!!!!! “Water sw open”. Raypak 266 digital. (18)

ajw22

TFP Expert

Gold Supporter

Silver Supporter

Bronze Supporter

TFP Guide

Jul 21, 2013
55,050
Northern NJ
Pool Size
35000
Surface
Plaster
Chlorine
Salt Water Generator
SWG Type
Pentair Intellichlor IC-60
  • May 29, 2020
  • Add bookmark
  • #14

Get rid of the splice and replace the 2 wire cable. Any 2 wire cable will work.

You must log in or register to reply here.

“Water sw open”. Raypak 266 digital. (2024)

FAQs

How to fix Raypak pool heater? ›

Go make sure there aren't any tripped circuit breakers in the fuse box, then check that the unit's time clock is set to the “On” position. Check Filters & Strainers: Problems with slow or inefficient heating, as well as overly noisy operation, can sometimes be traced back to dirty filters and strainers.

What does open water sensor mean on pool heater? ›

The model is inside the pool heater. I do not need the Aqualink model number. Anyways the answer is as I mentioned before. (open water temp sensor) That means the control board can no longer read the temperature of the incoming water.

Why is a pressure relief valve installed on a pool heater system? ›

The primary role of the pressure-relief valve is to release excess pressure in the water heater tank. If the valve fails to do this, pressure can continue to build past safe limits, typically around 150 PSI (pounds per square inch).

What is open outlet water heater? ›

For open-outlet (low-pressure) storage type electric water heaters, they are designed to supply only one serving point and the outlet is controlled by a special water mixer which maintains a vented passage for the air inside the tank to the atmosphere.

Which switch on a pool heater will close on proper water flow? ›

The first one is the pressure switch. This switch makes sure enough water is flowing through the unit before it will let the pool heater turn on. This means you must have the pump on and a clean filter for this switch to close and allow voltage to pass through.

What does water flow lockout mean on pool heater? ›

This is an Electric pool heater(heat pump) to me it sounds like either the unit isn't getting or seeing enough water flow. The pools filters might need to be cleaned or replaced, or the flow switch in the heater needs to be replaced or is blocked..

What is the VAC mode on a water heater? ›

Most water heaters have a setting on their temperature dial labeled “VAC” or “VACATION.” You've probably seen this on the thermostat and never knew what it was used for. Vacation Mode drops your water heater's temperature to conserve energy while you're not home to use your hot water.

Top Articles
Latest Posts
Article information

Author: Arline Emard IV

Last Updated:

Views: 5739

Rating: 4.1 / 5 (72 voted)

Reviews: 95% of readers found this page helpful

Author information

Name: Arline Emard IV

Birthday: 1996-07-10

Address: 8912 Hintz Shore, West Louie, AZ 69363-0747

Phone: +13454700762376

Job: Administration Technician

Hobby: Paintball, Horseback riding, Cycling, Running, Macrame, Playing musical instruments, Soapmaking

Introduction: My name is Arline Emard IV, I am a cheerful, gorgeous, colorful, joyous, excited, super, inquisitive person who loves writing and wants to share my knowledge and understanding with you.